PRODUCTS     
 
   ROOM AIR PURIFIERS
   AUSTIN
   ALLERAIR
   BIONAIRE
   HOLMES
    CAR AIR PURIFIERS
    AMAIRCARE
    GREEN AIR
    CENTRAL PURIFIERS
   AMAIRCARE
    HONEYWELL
    HUMIDIFIERS
   BIONAIRE
   HOLMES
    FANS
   BIONAIRE
   HOLMES
    AIR HEATERS
   BIONAIRE
   PATTON
    SMOKE GRABBER
   POLLENEX
    HOLMES
 
Guide for Buying the Air Purifier.
Buying the Air Purifier
Air purifier by indoor air quality problem.
True HEPA, ULPA and carbon filters.
Air purifier by the size of a cleaning area.
Buying the Humidifier
Benefits of utilization the humidifiers.
Types of humidifiers.
Warm Mist Humidifier vs. Cool Mist.
 
Air Purifier for the Size of a Cleaning Area.
 
 Maximum Cleaning Area.
The maximum cleaning area for any air purifier with the air filtration system is the size of the room in sq. ft. with the average height of the ceiling of 8 feet, in which the unit running on the highest setting (speed) can provide two complete air changes per hour.
It's enough to make the difference in the air quality noticeable. However, for best air cleaning result and a truly high air quality the number of complete air changes per hour should be 4 and over. So, always pay attention on the number of air changes per hour when looking at the size of a maximum cleaning area for the air purifiers. 
Do not forget, any air puirifier (air cleaner) is quite noisy when running on maximum speed.
It makes it very unlikely that you run the unit on maximum setting all day long.
The "Medium setting in normally used for day-time operation, while "Low" is best for a night time. Most air cleaning devices on Medium setting provide air flow 50 - 60 % of the High setting.
So, the actual cleaning area for the unit running on Medium setting will be the same 50 - 60 % of the maximum one.
The maximum cleaning area goes down as the height of the ceiling goes up.
For example, for the height of the ceiling of 12 ft. the actual cleaning area will be 75 % of the maximum area provided in Technical Specification, for the height of the ceiling of 16 ft. it's going to be 50 %.

On-Line Cleaning Area Size Calculator !
Use this calculator to get the size of the maximum cleaning area in sq. ft. for any desired number of air changes per hour in the room with any height of the ceiling in ft..
How to use this calculator.
1. From the technical specification on the air cleaning device find out the maximum air flow in CFM (cubic footot per minute),
2. Type this (or any other value) in the Air Flow field, hit Enter or left clikc of your mouse. The result should appear for preselected values of the height of the ceiling - 8 ft. and the number of air changes per hour - 2.
3. From the pull down menu select any desired number of air changes per hour and the height of the ceiling to get the result instantly. 
Air Flow: (type in then hit Enter) CFM cubic foot per minute
Height of the ceiling ft. average height 8 ft.
Number of Air Changes per hour n air changes per hour
 
Size of the Cleaning Area sq. ft. square foot
 
 
HOME PAGE
 
CUSTOMER SERVICE
 
PRODUCTS
 
BUYER'S GUIDE
 
CONTACT US
"InTech Marketing" ~
Air Solutions Company
Toll free:
E-mail: sales

© Copyright "InTech Marketing". All Rights Reserved.